Study-specific and risk-based coverage

Generate UAT package applies only to the selected study. New scripts retain its Account/study IDs, protocol/version, design revision and configured settings in the scope case. Confirm that baseline against the approved protocol before testing; switching studies reloads the displayed package even when both studies have the same revision number.

Generated tests include protocol-dependent operations and 17 FDA/Part 11 control checks covering validation risk, records/copies/retention, access/blinding, audit, sequencing, inputs/interfaces, training/accountability, change control, signing/linkage/identity, sessions, security, recovery, time/review and protocol assistance when used. These are a baseline, not a guarantee of every applicable FDA requirement. Sponsor and QA must assess predicate rules and deployment/procedural evidence and add study-specific tests before approving the script.

Use a qualified isolated test environment with synthetic subjects, test stock and isolated integrations. Record actual observations and objective evidence. For new packages, Pass and N/A require inputs or applicability assessment plus an evidence reference; N/A is not reported as passed. Configuration changes block approval, sign-off and initial activation under an outdated baseline. Historical packages are not retrospectively requalified.

See FDA clinical electronic-systems Q&A and Part 11 Scope and Application. QA release is an organizational decision, not FDA approval.

Purpose

Provide retained, audited intended-use evidence for the selected study before go-live (21 CFR 11.10(a), FDA clinical electronic-systems Q&A) and produce study-scoped datasets for submission or inspection. The scope case records identity/revisions and a SHA-256 configuration fingerprint; restricted allocation settings are reconciled separately by authorized unblinded reviewers, not disclosed to blinded QA.

Expected outcome

The Lifecycle & Exports tab shows a QA-released UAT package for the current design revision, activation is allowed, and submission files are downloaded with a SHA-256 manifest.

Prerequisites

An approved current design revision (Design Step 9). New packages use Author / Test Executor, independent System Owner / Business SME and independent QA Approver. Execution requires Studies.Manage; the System Owner requires that permission plus unblinded Randomization.Manage and Inventory.Manage; QA requires Audit.View. Older packages retain their original sign-off roles. Submission exports require Data.Export and Subjects.View, plus dataset permissions.

Section 1: The audited UAT package

  • Traceability matrix - applicable URS and FDA controls map to cases; inspect unexercised requirements and justified exclusions.
  • Pre-approved script - an independent authorized reviewer signs the Draft; the script SHA-256 is frozen.
  • Execution and evidence - actual inputs, observations, UTC time, results and evidence references are append-only; N/A is not a pass.
  • Deviations - failures remain in history and require root cause, risk impact, resolution and a passing retest before closure.
  • Sign-off - new packages use author/executor, independent System Owner and QA last. Each signer is a different person; QA cannot author, approve the script or execute a case. The released PDF and hash are retained.

Study identity in every export

Validation, ODM, DM and submission downloads are generated only for the requested study and retain its unique ID in their file names. RTSM listings include study/Account/version metadata; CDISC domains preserve their STUDYID layout. The ZIP contains hashed study-scope.json, manifest.csv and a README, so empty datasets retain their study context too. Historical released PDF bytes are not rewritten. Current traceability distinguishes matching, changed and legacy baselines.

Section 2: Activation gate

Moving from Setup to Active is blocked until a QA-released package exists for the current design revision. Any later design change requires a new package.

Section 3: Submission exports

  1. Subject and randomization - SDTM DM, DS, TV and the code-break log.
  2. IP exposure - SDTM EX.
  3. Supply accountability - lots, shipments, kit chain of custody, reconciliation.
  4. Cold chain - temperature readings and excursions with QA decisions.
  5. GxP audit trail - audit trail with old/new values and the user access log.
  6. eCTD validation artefacts - master randomization list (unblinded only), URS traceability and the released UAT PDF.

The ZIP package contains manifest.csv with record counts and SHA-256 per file and a README stating BLINDED or UNBLINDED status. Every export is recorded in the audit trail.

Troubleshooting and checks

"Not available" in the manifest means the source does not exist yet, for example no released UAT package. "Withheld" means your role cannot receive that dataset. Blinded users receive masked treatment columns.

Related articles

This guide supports training and does not authorize clinical decisions, override access controls or establish regulatory compliance. The approved protocol and organizational procedures remain authoritative.